Eaton/Moeller FAZ-B6/1 single pole, 6 AMP circuit breaker that has a B-Curve trip characteristic and is designed for low-level short-circuit faults in control wiring. This miniature circuit breaker mounts on standard 35mm DIN rail, has an on/off front mounted toggle switch and the industry standard width for single pole breakers at 18mm. A side mounted auxiliary can be added to the FAZ-B6/1 for signalling purposes in addition to shunt and under voltage trips for complete motor protection.

Catalog Page / Specifications

List Price: $84.00
Our Price: $14.97
Savings: $69.03

Quantity in Stock:(Out of Stock)

Availability : Out of Stock - Can ship in 1-2 days
Product Code: FAZ-B6-1
Qty:

Description Detailed Specifications
 
The Eaton FAZ line of miniature circuit breakers includes a broad range of devices defined as “supplementary protectors.” These breakers comply with UL 1077 and CSA 22.2 No. 235 regulations defining supplementary over-current protection. In these applications, branch circuit protection is not required, or is provided by a separate device like a fuse or molded case circuit breaker. FAZ Supplementary Protectors are typically used for control circuits, lighting, business equipment, appliances and a range of other applications where “closer” protection is desired than that offered by a branch circuit protection device.

All breakers mount on a standard 35mm DIN-rail. Each device has box terminals that accept multiple conductors. Bus Connectors and Feeder Terminals facilitate mounting and wiring of multiple miniature circuit breaker arrays in control panel assemblies. Power to the circuit breakers can also be fed from the line or load side.
Technical Specifications
  • Complete range of ULT 1077 DIN rail mounted supplementary protectors from 0.5 to 63A current rating
  • Current limiting design provides fast short-circuit interruption that reduces the let-through energy that can damage the circuit
  • Thermal-magnetic overcurrent protection
  • Trip-free design—breaker can not be defeated by holding the handle in the ON position
  • Field-installable shunt trip auxiliary switch and undervoltage release
  • For use in applications for which UL 1077 or CSAT C22.2 No. 235 are required
  • Complete busbar system available for quickly installing multiple breakers in panel assembly
  • Possibility for sealing the toggle in ON or OFF position