{"title":"Square D \/ Telemecanique","description":"\u003ch2\u003eSquare D\/Telemecanique\u003c\/h2\u003e\n\u003cp\u003eTelemecanique and Square D are dedicated to providing quality solutions for distributing and monitoring electrical power. Their selection of high-quality contactors and motor starters is backed by premium quality, reliability and energy-saving design. From residential load centers and metering products to commercial panelboards, Telemecanique Square D is the backbone of today's energy for homes and businesses. Shop IMC-Direct for Square D motor starters, overload relays, thermal heaters and more today!\u003c\/p\u003e","products":[{"product_id":"8502sao12s","title":"8502SA012S","description":"Class 8502SAO12S magnetic NEMA contactors are used for full voltage starting and stopping AC squirrel cage motors. Motor overload protection is provided by adding melting alloy type thermal overload relays. Class 8502SA0 starters are available in NEMA Sizes 00-7. Type S starters are designed for operation at 600 Volts AC, 50-60 Hertz.\u003cbr\u003e\u003cbr\u003e\nThese Square D starters from NEMA size 00-6 are provided with a melting alloy thermal overload relay as standard. Interchangeable thermal units are available in standard trip (Class 20) Sizes\n00-6, quick trip (Class 10) Sizes 00-4, and slow trip (Class 30) Sizes 00-3. Single-phase starters use one thermal unit, 3-phase starters use three thermal units.","brand":"Square D \/ Telemecanique","offers":[{"title":"Default Title","offer_id":48222159438062,"sku":"8502SAO12S","price":146.47,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/8502SAO12S-2.jpg?v=1782784282"},{"product_id":"8502sb02v01s","title":"8502SB02V01S","description":"Class 8502SBO2S magnetic NEMA contactors are used for full voltage starting and stopping AC squirrel cage motors. Motor overload protection is provided by adding melting alloy type thermal overload relays. Class 8502SB0 starters are available in NEMA Sizes 00-7. Type S starters are designed for operation at 600 Volts AC, 50-60 Hertz.\u003cbr\u003e\u003cbr\u003e\nThese Square D starters from NEMA size 00-6 are provided with a melting alloy thermal overload relay as standard. Interchangeable thermal units are available in standard trip (Class 20) Sizes\n00-6, quick trip (Class 10) Sizes 00-4, and slow trip (Class 30) Sizes 00-3. Single-phase starters use one thermal unit, 3-phase starters use three thermal units.","brand":"Square D \/ Telemecanique","offers":[{"title":"Default Title","offer_id":48222159470830,"sku":"8502SB02V01S","price":179.92,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/8502SB02V01S-2.jpg?v=1782784284"},{"product_id":"8502sb02v02s","title":"8502SB02V02S","description":"Class 8502SBO2S magnetic NEMA contactors are used for full voltage starting and stopping AC squirrel cage motors. Motor overload protection is provided by adding melting alloy type thermal overload relays. Class 8502SB0 starters are available in NEMA Sizes 00-7. Type S starters are designed for operation at 600 Volts AC, 50-60 Hertz.\u003cbr\u003e\u003cbr\u003e\nThese Square D starters from NEMA size 00-6 are provided with a melting alloy thermal overload relay as standard. Interchangeable thermal units are available in standard trip (Class 20) Sizes\n00-6, quick trip (Class 10) Sizes 00-4, and slow trip (Class 30) Sizes 00-3. Single-phase starters use one thermal unit, 3-phase starters use three thermal units.","brand":"Square D \/ Telemecanique","offers":[{"title":"Default Title","offer_id":48222159503598,"sku":"8502SB02V02S","price":274.67,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/8502SB02V02S-2.jpg?v=1782784284"},{"product_id":"8502sb02v03","title":"8502SB02V03","description":"Class 8502SBO2S magnetic NEMA contactors are used for full voltage starting and stopping AC squirrel cage motors. Motor overload protection is provided by adding melting alloy type thermal overload relays. Class 8502SB0 starters are available in NEMA Sizes 00-7. Type S starters are designed for operation at 600 Volts AC, 50-60 Hertz.\u003cbr\u003e\u003cbr\u003e\nThese Square D starters from NEMA size 00-6 are provided with a melting alloy thermal overload relay as standard. Interchangeable thermal units are available in standard trip (Class 20) Sizes\n00-6, quick trip (Class 10) Sizes 00-4, and slow trip (Class 30) Sizes 00-3. Single-phase starters use one thermal unit, 3-phase starters use three thermal units.","brand":"Square D \/ Telemecanique","offers":[{"title":"Default Title","offer_id":48222159536366,"sku":"8502SB02V03","price":179.92,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/8502SB02V03-2.jpg?v=1782784286"},{"product_id":"8502sb02v06","title":"8502SB02V06","description":"Class 8502SBO2S magnetic NEMA contactors are used for full voltage starting and stopping AC squirrel cage motors. Motor overload protection is provided by adding melting alloy type thermal overload relays. Class 8502SB0 starters are available in NEMA Sizes 00-7. Type S starters are designed for operation at 600 Volts AC, 50-60 Hertz.\u003cbr\u003e\u003cbr\u003e\nThese Square D starters from NEMA size 00-6 are provided with a melting alloy thermal overload relay as standard. Interchangeable thermal units are available in standard trip (Class 20) Sizes\n00-6, quick trip (Class 10) Sizes 00-4, and slow trip (Class 30) Sizes 00-3. Single-phase starters use one thermal unit, 3-phase starters use three thermal units.","brand":"Square D \/ Telemecanique","offers":[{"title":"Default Title","offer_id":48222159569134,"sku":"8502SB02V06","price":179.92,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/8502SB02V06-2.jpg?v=1782784287"},{"product_id":"8502sb02v08","title":"8502SB02V08","description":"Class 8502SBO2S magnetic NEMA contactors are used for full voltage starting and stopping AC squirrel cage motors. Motor overload protection is provided by adding melting alloy type thermal overload relays. Class 8502SB0 starters are available in NEMA Sizes 00-7. Type S starters are designed for operation at 600 Volts AC, 50-60 Hertz.\u003cbr\u003e\u003cbr\u003e\nThese Square D starters from NEMA size 00-6 are provided with a melting alloy thermal overload relay as standard. Interchangeable thermal units are available in standard trip (Class 20) Sizes\n00-6, quick trip (Class 10) Sizes 00-4, and slow trip (Class 30) Sizes 00-3. Single-phase starters use one thermal unit, 3-phase starters use three thermal units.","brand":"Square D \/ Telemecanique","offers":[{"title":"Default Title","offer_id":48222159601902,"sku":"8502SB02V08","price":179.92,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/8502SB02V08-2.jpg?v=1782784290"},{"product_id":"8502sbo2s","title":"8502SB02S","description":"Class 8502SBO2S magnetic NEMA contactors are used for full voltage starting and stopping AC squirrel cage motors. Motor overload protection is provided by adding melting alloy type thermal overload relays. Class 8502SB0 starters are available in NEMA Sizes 00-7. Type S starters are designed for operation at 600 Volts AC, 50-60 Hertz.\u003cbr\u003e\u003cbr\u003e\nThese Square D starters from NEMA size 00-6 are provided with a melting alloy thermal overload relay as standard. Interchangeable thermal units are available in standard trip (Class 20) Sizes\n00-6, quick trip (Class 10) Sizes 00-4, and slow trip (Class 30) Sizes 00-3. Single-phase starters use one thermal unit, 3-phase starters use three thermal units.","brand":"Square D \/ Telemecanique","offers":[{"title":"Default Title","offer_id":48222159634670,"sku":"8502SBO2S","price":179.92,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/8502SBO2S-2.jpg?v=1782784290"},{"product_id":"8502sco2","title":"8502SC02","description":"Class 8502SCO2S magnetic NEMA contactors are used for full voltage starting and stopping AC squirrel cage motors. Motor overload protection is provided by adding melting alloy type thermal overload relays. Class 8502SC0 starters are available in NEMA Sizes 00-7. Type S starters are designed for operation at 600 Volts AC, 50-60 Hertz.\u003cbr\u003e\u003cbr\u003e\nThese Square D starters from NEMA size 00-6 are provided with a melting alloy thermal overload relay as standard. Interchangeable thermal units are available in standard trip (Class 20) Sizes\n00-6, quick trip (Class 10) Sizes 00-4, and slow trip (Class 30) Sizes 00-3. Single-phase starters use one thermal unit, 3-phase starters use three thermal units.","brand":"Square D \/ Telemecanique","offers":[{"title":"Default Title","offer_id":48222159667438,"sku":"8502SCO2","price":210.78,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/8502SCO2-2.jpg?v=1782784291"},{"product_id":"8502sco2s","title":"8502SC02S","description":"Class 8502SCO2S magnetic NEMA contactors are used for full voltage starting and stopping AC squirrel cage motors. Motor overload protection is provided by adding melting alloy type thermal overload relays. Class 8502SC0 starters are available in NEMA Sizes 00-7. Type S starters are designed for operation at 600 Volts AC, 50-60 Hertz.\u003cbr\u003e\u003cbr\u003e\nThese Square D starters from NEMA size 00-6 are provided with a melting alloy thermal overload relay as standard. Interchangeable thermal units are available in standard trip (Class 20) Sizes\n00-6, quick trip (Class 10) Sizes 00-4, and slow trip (Class 30) Sizes 00-3. Single-phase starters use one thermal unit, 3-phase starters use three thermal units.","brand":"Square D \/ Telemecanique","offers":[{"title":"Default Title","offer_id":48222159700206,"sku":"8502SCO2S","price":210.78,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/8502SCO2S-2.jpg?v=1782784292"},{"product_id":"8502sco2v01s","title":"8502SC02V01S","description":"Class 8502SCO2S magnetic NEMA contactors are used for full voltage starting and stopping AC squirrel cage motors. Motor overload protection is provided by adding melting alloy type thermal overload relays. Class 8502SC0 starters are available in NEMA Sizes 00-7. Type S starters are designed for operation at 600 Volts AC, 50-60 Hertz.\u003cbr\u003e\u003cbr\u003e\nThese Square D starters from NEMA size 00-6 are provided with a melting alloy thermal overload relay as standard. Interchangeable thermal units are available in standard trip (Class 20) Sizes\n00-6, quick trip (Class 10) Sizes 00-4, and slow trip (Class 30) Sizes 00-3. Single-phase starters use one thermal unit, 3-phase starters use three thermal units.","brand":"Square D \/ Telemecanique","offers":[{"title":"Default Title","offer_id":48222159732974,"sku":"8502SCO2V01S","price":210.78,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/8502SCO2V01S-2.jpg?v=1782784295"},{"product_id":"8502sco2v02s","title":"8502SC02V02S","description":"Class 8502SCO2S magnetic NEMA contactors are used for full voltage starting and stopping AC squirrel cage motors. Motor overload protection is provided by adding melting alloy type thermal overload relays. Class 8502SC0 starters are available in NEMA Sizes 00-7. Type S starters are designed for operation at 600 Volts AC, 50-60 Hertz.\u003cbr\u003e\u003cbr\u003e\nThese Square D starters from NEMA size 00-6 are provided with a melting alloy thermal overload relay as standard. Interchangeable thermal units are available in standard trip (Class 20) Sizes\n00-6, quick trip (Class 10) Sizes 00-4, and slow trip (Class 30) Sizes 00-3. Single-phase starters use one thermal unit, 3-phase starters use three thermal units.","brand":"Square D \/ Telemecanique","offers":[{"title":"Default Title","offer_id":48222159765742,"sku":"8502SCO2V02S","price":210.78,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/8502SCO2V02S-2.jpg?v=1782784295"},{"product_id":"8502sco2v03","title":"8502SC02V03","description":"Class 8502SCO2 magnetic NEMA contactors are used for full voltage starting and stopping AC squirrel cage motors. Motor overload protection is provided by adding melting alloy type thermal overload relays. Class 8502SC0 starters are available in NEMA Sizes 00-7. Type S starters are designed for operation at 600 Volts AC, 50-60 Hertz.\u003cbr\u003e\u003cbr\u003e\nThese Square D starters from NEMA size 00-6 are provided with a melting alloy thermal overload relay as standard. Interchangeable thermal units are available in standard trip (Class 20) Sizes\n00-6, quick trip (Class 10) Sizes 00-4, and slow trip (Class 30) Sizes 00-3. Single-phase starters use one thermal unit, 3-phase starters use three thermal units.","brand":"Square D \/ Telemecanique","offers":[{"title":"Default Title","offer_id":48222159798510,"sku":"8502SCO2V03","price":210.78,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/8502SCO2V03-2.jpg?v=1782784296"},{"product_id":"8502sco2v06","title":"8502SC02V06","description":"Class 8502SCO2 magnetic NEMA contactors are used for full voltage starting and stopping AC squirrel cage motors. Motor overload protection is provided by adding melting alloy type thermal overload relays. Class 8502SC0 starters are available in NEMA Sizes 00-7. Type S starters are designed for operation at 600 Volts AC, 50-60 Hertz.\u003cbr\u003e\u003cbr\u003e\nThese Square D starters from NEMA size 00-6 are provided with a melting alloy thermal overload relay as standard. Interchangeable thermal units are available in standard trip (Class 20) Sizes\n00-6, quick trip (Class 10) Sizes 00-4, and slow trip (Class 30) Sizes 00-3. Single-phase starters use one thermal unit, 3-phase starters use three thermal units.","brand":"Square D \/ Telemecanique","offers":[{"title":"Default Title","offer_id":48222159831278,"sku":"8502SCO2V06","price":210.78,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/8502SCO2V06-2.jpg?v=1782784297"},{"product_id":"8502sco2v08","title":"8502SC02V08","description":"Class 8502SCO2 magnetic NEMA contactors are used for full voltage starting and stopping AC squirrel cage motors. Motor overload protection is provided by adding melting alloy type thermal overload relays. Class 8502SC0 starters are available in NEMA Sizes 00-7. Type S starters are designed for operation at 600 Volts AC, 50-60 Hertz.\u003cbr\u003e\u003cbr\u003e\nThese Square D starters from NEMA size 00-6 are provided with a melting alloy thermal overload relay as standard. Interchangeable thermal units are available in standard trip (Class 20) Sizes\n00-6, quick trip (Class 10) Sizes 00-4, and slow trip (Class 30) Sizes 00-3. Single-phase starters use one thermal unit, 3-phase starters use three thermal units.","brand":"Square D \/ Telemecanique","offers":[{"title":"Default Title","offer_id":48222160224494,"sku":"8502SCO2V08","price":210.78,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/8502SCO2V08-2.jpg?v=1782784303"},{"product_id":"8502sdo2","title":"8502SD02","description":"Class 8502SDO2 magnetic NEMA contactors are used for full voltage starting and stopping AC squirrel cage motors. Motor overload protection is provided by adding melting alloy type thermal overload relays. Class 8502SD0 starters are available in NEMA Sizes 00-7. Type S starters are designed for operation at 600 Volts AC, 50-60 Hertz.\u003cbr\u003e\u003cbr\u003e\nThese Square D starters from NEMA size 00-6 are provided with a melting alloy thermal overload relay as standard. Interchangeable thermal units are available in standard trip (Class 20) Sizes\n00-6, quick trip (Class 10) Sizes 00-4, and slow trip (Class 30) Sizes 00-3. Single-phase starters use one thermal unit, 3-phase starters use three thermal units.","brand":"Square D \/ Telemecanique","offers":[{"title":"Default Title","offer_id":48222160257262,"sku":"8502SDO2","price":525.89,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/8502SDO2-2.jpg?v=1782784300"},{"product_id":"8502sdo2s","title":"8502SD02S","description":"Class 8502SDO2S magnetic NEMA contactors are used for full voltage starting and stopping AC squirrel cage motors. Motor overload protection is provided by adding melting alloy type thermal overload relays. Class 8502SD0 starters are available in NEMA Sizes 00-7. Type S starters are designed for operation at 600 Volts AC, 50-60 Hertz.\u003cbr\u003e\u003cbr\u003e\nThese Square D starters from NEMA size 00-6 are provided with a melting alloy thermal overload relay as standard. Interchangeable thermal units are available in standard trip (Class 20) Sizes\n00-6, quick trip (Class 10) Sizes 00-4, and slow trip (Class 30) Sizes 00-3. Single-phase starters use one thermal unit, 3-phase starters use three thermal units.","brand":"Square D \/ Telemecanique","offers":[{"title":"Default Title","offer_id":48222160290030,"sku":"8502SDO2S","price":525.89,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/8502SDO2S-2.jpg?v=1782784302"},{"product_id":"8502sdo2v01s","title":"8502SD02V01S","description":"Class 8502SDO2V01S magnetic NEMA contactors are used for full voltage starting and stopping AC squirrel cage motors. Motor overload protection is provided by adding melting alloy type thermal overload relays. Class 8502SD0 starters are available in NEMA Sizes 00-7. Type S starters are designed for operation at 600 Volts AC, 50-60 Hertz.\u003cbr\u003e\u003cbr\u003e\nThese Square D starters from NEMA size 00-6 are provided with a melting alloy thermal overload relay as standard. Interchangeable thermal units are available in standard trip (Class 20) Sizes\n00-6, quick trip (Class 10) Sizes 00-4, and slow trip (Class 30) Sizes 00-3. Single-phase starters use one thermal unit, 3-phase starters use three thermal units.","brand":"Square D \/ Telemecanique","offers":[{"title":"Default Title","offer_id":48222160322798,"sku":"8502SDO2V01S","price":525.89,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/8502SDO2V01S-2.jpg?v=1782784303"},{"product_id":"8502sdo2v02s","title":"8502SD02V02S","description":"Class 8502SDO2V02S magnetic NEMA contactors are used for full voltage starting and stopping AC squirrel cage motors. Motor overload protection is provided by adding melting alloy type thermal overload relays. Class 8502SD0 starters are available in NEMA Sizes 00-7. Type S starters are designed for operation at 600 Volts AC, 50-60 Hertz.\u003cbr\u003e\u003cbr\u003e\nThese Square D starters from NEMA size 00-6 are provided with a melting alloy thermal overload relay as standard. Interchangeable thermal units are available in standard trip (Class 20) Sizes\n00-6, quick trip (Class 10) Sizes 00-4, and slow trip (Class 30) Sizes 00-3. Single-phase starters use one thermal unit, 3-phase starters use three thermal units.","brand":"Square D \/ Telemecanique","offers":[{"title":"Default Title","offer_id":48222160355566,"sku":"8502SDO2V02S","price":525.89,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/8502SDO2V02S-2.jpg?v=1782784305"},{"product_id":"8502sdo2v03","title":"8502SD02V03","description":"Class 8502SDO2V03 magnetic NEMA contactors are used for full voltage starting and stopping AC squirrel cage motors. Motor overload protection is provided by adding melting alloy type thermal overload relays. Class 8502SD0 starters are available in NEMA Sizes 00-7. Type S starters are designed for operation at 600 Volts AC, 50-60 Hertz.\u003cbr\u003e\u003cbr\u003e\nThese Square D starters from NEMA size 00-6 are provided with a melting alloy thermal overload relay as standard. Interchangeable thermal units are available in standard trip (Class 20) Sizes\n00-6, quick trip (Class 10) Sizes 00-4, and slow trip (Class 30) Sizes 00-3. Single-phase starters use one thermal unit, 3-phase starters use three thermal units.","brand":"Square D \/ Telemecanique","offers":[{"title":"Default Title","offer_id":48222160388334,"sku":"8502SDO2V03","price":525.89,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/8502SDO2V03-2.jpg?v=1782784305"},{"product_id":"8502sdo2v06","title":"8502SD02V06","description":"Class 8502SDO2V08 magnetic NEMA contactors are used for full voltage starting and stopping AC squirrel cage motors. Motor overload protection is provided by adding melting alloy type thermal overload relays. Class 8502SD0 starters are available in NEMA Sizes 00-7. Type S starters are designed for operation at 600 Volts AC, 50-60 Hertz.\u003cbr\u003e\u003cbr\u003e\nThese Square D starters from NEMA size 00-6 are provided with a melting alloy thermal overload relay as standard. Interchangeable thermal units are available in standard trip (Class 20) Sizes\n00-6, quick trip (Class 10) Sizes 00-4, and slow trip (Class 30) Sizes 00-3. Single-phase starters use one thermal unit, 3-phase starters use three thermal units.","brand":"Square D \/ Telemecanique","offers":[{"title":"Default Title","offer_id":48222160453870,"sku":"8502SDO2V06","price":525.89,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/8502SDO2V06-2.jpg?v=1782784307"},{"product_id":"8502sdo2v08","title":"8502SD02V08","description":"Class 8502SDO2V08 magnetic NEMA contactors are used for full voltage starting and stopping AC squirrel cage motors. Motor overload protection is provided by adding melting alloy type thermal overload relays. Class 8502SD0 starters are available in NEMA Sizes 00-7. Type S starters are designed for operation at 600 Volts AC, 50-60 Hertz.\u003cbr\u003e\u003cbr\u003e\nThese Square D starters from NEMA size 00-6 are provided with a melting alloy thermal overload relay as standard. Interchangeable thermal units are available in standard trip (Class 20) Sizes\n00-6, quick trip (Class 10) Sizes 00-4, and slow trip (Class 30) Sizes 00-3. Single-phase starters use one thermal unit, 3-phase starters use three thermal units.","brand":"Square D \/ Telemecanique","offers":[{"title":"Default Title","offer_id":48222161535214,"sku":"8502SDO2V08","price":525.89,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/8502SDO2V08-2.jpg?v=1782784308"},{"product_id":"8502seo2","title":"8502SE02","description":"Class 8502SEO2 magnetic NEMA contactors are used for full voltage starting and stopping AC squirrel cage motors. Motor overload protection is provided by adding melting alloy type thermal overload relays. Class 8502SE0 starters are available in NEMA Sizes 00-7. Type S starters are designed for operation at 600 Volts AC, 50-60 Hertz.\u003cbr\u003e\u003cbr\u003e\nThese Square D starters from NEMA size 00-6 are provided with a melting alloy thermal overload relay as standard. Interchangeable thermal units are available in standard trip (Class 20) Sizes\n00-6, quick trip (Class 10) Sizes 00-4, and slow trip (Class 30) Sizes 00-3. Single-phase starters use one thermal unit, 3-phase starters use three thermal units.","brand":"Square D \/ Telemecanique","offers":[{"title":"Default Title","offer_id":48222161862894,"sku":"8502SEO2","price":619.31,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/8502SEO2-2.jpg?v=1782784310"},{"product_id":"8502seo2s","title":"8502SE02S","description":"Class 8502SEO2S magnetic NEMA contactors are used for full voltage starting and stopping AC squirrel cage motors. Motor overload protection is provided by adding melting alloy type thermal overload relays. Class 8502SE0 starters are available in NEMA Sizes 00-7. Type S starters are designed for operation at 600 Volts AC, 50-60 Hertz.\u003cbr\u003e\u003cbr\u003e\nThese Square D starters from NEMA size 00-6 are provided with a melting alloy thermal overload relay as standard. Interchangeable thermal units are available in standard trip (Class 20) Sizes\n00-6, quick trip (Class 10) Sizes 00-4, and slow trip (Class 30) Sizes 00-3. Single-phase starters use one thermal unit, 3-phase starters use three thermal units.","brand":"Square D \/ Telemecanique","offers":[{"title":"Default Title","offer_id":48222161895662,"sku":"8502SEO2S","price":619.31,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/8502SEO2S-2.jpg?v=1782784310"},{"product_id":"8502seo2v01s","title":"8502SE02V01S","description":"Class 8502SEO2V01S magnetic NEMA contactors are used for full voltage starting and stopping AC squirrel cage motors. Motor overload protection is provided by adding melting alloy type thermal overload relays. Class 8502SE0 starters are available in NEMA Sizes 00-7. Type S starters are designed for operation at 600 Volts AC, 50-60 Hertz.\u003cbr\u003e\u003cbr\u003e\nThese Square D starters from NEMA size 00-6 are provided with a melting alloy thermal overload relay as standard. Interchangeable thermal units are available in standard trip (Class 20) Sizes\n00-6, quick trip (Class 10) Sizes 00-4, and slow trip (Class 30) Sizes 00-3. Single-phase starters use one thermal unit, 3-phase starters use three thermal units.","brand":"Square D \/ Telemecanique","offers":[{"title":"Default Title","offer_id":48222162059502,"sku":"8502SEO2V01S","price":619.31,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/8502SEO2V01S-2.jpg?v=1782784312"},{"product_id":"8502seo2v02s","title":"8502SE02V02S","description":"Class 8502SEO2V02S magnetic NEMA contactors are used for full voltage starting and stopping AC squirrel cage motors. Motor overload protection is provided by adding melting alloy type thermal overload relays. Class 8502SE0 starters are available in NEMA Sizes 00-7. Type S starters are designed for operation at 600 Volts AC, 50-60 Hertz.\u003cbr\u003e\u003cbr\u003e\nThese Square D starters from NEMA size 00-6 are provided with a melting alloy thermal overload relay as standard. Interchangeable thermal units are available in standard trip (Class 20) Sizes\n00-6, quick trip (Class 10) Sizes 00-4, and slow trip (Class 30) Sizes 00-3. Single-phase starters use one thermal unit, 3-phase starters use three thermal units.","brand":"Square D \/ Telemecanique","offers":[{"title":"Default Title","offer_id":48222162125038,"sku":"8502SEO2V02S","price":619.31,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/8502SEO2V02S-2.jpg?v=1782784313"},{"product_id":"8502seo2v03","title":"8502SE02V03","description":"Class 8502SEO2V03 magnetic NEMA contactors are used for full voltage starting and stopping AC squirrel cage motors. Motor overload protection is provided by adding melting alloy type thermal overload relays. Class 8502SE0 starters are available in NEMA Sizes 00-7. Type S starters are designed for operation at 600 Volts AC, 50-60 Hertz.\u003cbr\u003e\u003cbr\u003e\nThese Square D starters from NEMA size 00-6 are provided with a melting alloy thermal overload relay as standard. Interchangeable thermal units are available in standard trip (Class 20) Sizes\n00-6, quick trip (Class 10) Sizes 00-4, and slow trip (Class 30) Sizes 00-3. Single-phase starters use one thermal unit, 3-phase starters use three thermal units.","brand":"Square D \/ Telemecanique","offers":[{"title":"Default Title","offer_id":48222162157806,"sku":"8502SEO2V03","price":619.31,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/8502SEO2V03-2.jpg?v=1782784315"},{"product_id":"8502seo2v08","title":"8502SE02V08","description":"Class 8502SEO2V08 magnetic NEMA contactors are used for full voltage starting and stopping AC squirrel cage motors. Motor overload protection is provided by adding melting alloy type thermal overload relays. Class 8502SE0 starters are available in NEMA Sizes 00-7. Type S starters are designed for operation at 600 Volts AC, 50-60 Hertz.\u003cbr\u003e\u003cbr\u003e\nThese Square D starters from NEMA size 00-6 are provided with a melting alloy thermal overload relay as standard. Interchangeable thermal units are available in standard trip (Class 20) Sizes\n00-6, quick trip (Class 10) Sizes 00-4, and slow trip (Class 30) Sizes 00-3. Single-phase starters use one thermal unit, 3-phase starters use three thermal units.","brand":"Square D \/ Telemecanique","offers":[{"title":"Default Title","offer_id":48222162190574,"sku":"8502SEO2V08","price":619.31,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/8502SEO2V08-2.jpg?v=1782784316"},{"product_id":"8536sa012v01s","title":"8536SA012V01S","description":"Class 8536SAO12S Type S magnetic starters are used for full voltage starting and stopping AC squirrel cage motors. Motor overload protection is provided by melting alloy type thermal overload relays. Class 8536SA0 starters are available in NEMA Sizes 00-7. Type S starters are designed for operation at 600 Volts AC, 50-60 Hertz.\u003cbr\u003e\u003cbr\u003e\nThese Square D starters from NEMA size 00-6 are provided with a melting alloy thermal overload relay as standard. Interchangeable thermal units are available in standard trip (Class 20) Sizes\n00-6, quick trip (Class 10) Sizes 00-4, and slow trip (Class 30) Sizes 00-3. Single-phase starters use one thermal unit, 3-phase starters use three thermal units.","brand":"Square D \/ Telemecanique","offers":[{"title":"Default Title","offer_id":48222162223342,"sku":"8536SA012V01S","price":202.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/8536SA012V01S-2.jpg?v=1782784322"},{"product_id":"8536sa012v02s","title":"8536SA012V02S","description":"Class 8536SAO12V02S Type S magnetic starters are used for full voltage starting and stopping AC squirrel cage motors. Motor overload protection is provided by melting alloy type thermal overload relays. Class 8536SA0 starters are available in NEMA Sizes 00-7. Type S starters are designed for operation at 600 Volts AC, 50-60 Hertz.\u003cbr\u003e\u003cbr\u003e\nThese Square D starters from NEMA size 00-6 are provided with a melting alloy thermal overload relay as standard. Interchangeable thermal units are available in standard trip (Class 20) Sizes\n00-6, quick trip (Class 10) Sizes 00-4, and slow trip (Class 30) Sizes 00-3. Single-phase starters use one thermal unit, 3-phase starters use three thermal units.","brand":"Square D \/ Telemecanique","offers":[{"title":"Default Title","offer_id":48222162256110,"sku":"8536SA012V02S","price":202.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/8536SA012V02S-2.jpg?v=1782784319"},{"product_id":"8536sa012v08s","title":"8536SA012V08S","description":"Class 8536SAO12V08S Type S magnetic starters are used for full voltage starting and stopping AC squirrel cage motors. Motor overload protection is provided by melting alloy type thermal overload relays. Class 8536SA0 starters are available in NEMA Sizes 00-7. Type S starters are designed for operation at 600 Volts AC, 50-60 Hertz.\u003cbr\u003e\u003cbr\u003e\nThese Square D starters from NEMA size 00-6 are provided with a melting alloy thermal overload relay as standard. Interchangeable thermal units are available in standard trip (Class 20) Sizes\n00-6, quick trip (Class 10) Sizes 00-4, and slow trip (Class 30) Sizes 00-3. Single-phase starters use one thermal unit, 3-phase starters use three thermal units.","brand":"Square D \/ Telemecanique","offers":[{"title":"Default Title","offer_id":48222162288878,"sku":"8536SA012V08S","price":202.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/8536SA012V08S-2.jpg?v=1782784321"},{"product_id":"8536sao12","title":"8536SA012","description":"Class 8536SAO12 magnetic starters are used for full voltage starting and stopping AC squirrel cage motors. Motor overload protection is provided by melting alloy type thermal overload relays. Class 8536SA0 starters are available in NEMA Sizes 00-7. Type S starters are designed for operation at 600 Volts AC, 50-60 Hertz.\u003cbr\u003e\u003cbr\u003e\nThese Square D starters from NEMA size 00-6 are provided with a melting alloy thermal overload relay as standard. Interchangeable thermal units are available in standard trip (Class 20) Sizes\n00-6, quick trip (Class 10) Sizes 00-4, and slow trip (Class 30) Sizes 00-3. Single-phase starters use one thermal unit, 3-phase starters use three thermal units.","brand":"Square D \/ Telemecanique","offers":[{"title":"Default Title","offer_id":48222162321646,"sku":"8536SAO12","price":202.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/8536SAO12-2.jpg?v=1782784321"},{"product_id":"8536sbo2","title":"8536SB02","description":"Class 8536SBO2 magnetic starters are used for full voltage starting and stopping AC squirrel cage motors. Motor overload protection is provided by melting alloy type thermal overload relays. Class 8536SB02 starters are available in NEMA Sizes 00-7. Type S starters are designed for operation at 600 Volts AC, 50-60 Hertz.\u003cbr\u003e\u003cbr\u003e\nThese Square D starters from NEMA size 00-6 are provided with a melting alloy thermal overload relay as standard. Interchangeable thermal units are available in standard trip (Class 20) Sizes\n00-6, quick trip (Class 10) Sizes 00-4, and slow trip (Class 30) Sizes 00-3. Single-phase starters use one thermal unit, 3-phase starters use three thermal units.","brand":"Square D \/ Telemecanique","offers":[{"title":"Default Title","offer_id":48222162354414,"sku":"8536SBO2","price":269.64,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/8536SBO2-2.jpg?v=1782784324"},{"product_id":"8536sbo2s","title":"8536SB02S","description":"Class 8536SBO2S Type S magnetic starters are used for full voltage starting and stopping AC squirrel cage motors. Motor overload protection is provided by melting alloy type thermal overload relays. Class 8536SB0 starters are available in NEMA Sizes 00-7. Type S starters are designed for operation at 600 Volts AC, 50-60 Hertz.\u003cbr\u003e\u003cbr\u003e\nThese Square D starters from NEMA size 00-6 are provided with a melting alloy thermal overload relay as standard. Interchangeable thermal units are available in standard trip (Class 20) Sizes\n00-6, quick trip (Class 10) Sizes 00-4, and slow trip (Class 30) Sizes 00-3. Single-phase starters use one thermal unit, 3-phase starters use three thermal units.","brand":"Square D \/ Telemecanique","offers":[{"title":"Default Title","offer_id":48222162387182,"sku":"8536SBO2S","price":269.64,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/8536SBO2S-2.jpg?v=1782784326"},{"product_id":"8536sbo2v01s","title":"8536SBO2V01S","description":"Class 8536SBO2V01S Type S magnetic starters are used for full voltage starting and stopping AC squirrel cage motors. Motor overload protection is provided by melting alloy type thermal overload relays. Class 8536SB0 starters are available in NEMA Sizes 00-7. Type S starters are designed for operation at 600 Volts AC, 50-60 Hertz.\u003cbr\u003e\u003cbr\u003e\nThese Square D starters from NEMA size 00-6 are provided with a melting alloy thermal overload relay as standard. Interchangeable thermal units are available in standard trip (Class 20) Sizes\n00-6, quick trip (Class 10) Sizes 00-4, and slow trip (Class 30) Sizes 00-3. Single-phase starters use one thermal unit, 3-phase starters use three thermal units.","brand":"Square D \/ Telemecanique","offers":[{"title":"Default Title","offer_id":48222162419950,"sku":"8536SBO2V01S","price":298.08,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/8536SBO2V01S-2.jpg?v=1782784326"},{"product_id":"8536sbo2v02s","title":"8536SBO2V02S","description":"Class 8536SBO2V02S Type S magnetic starters are used for full voltage starting and stopping AC squirrel cage motors. Motor overload protection is provided by melting alloy type thermal overload relays. Class 8536SB0 starters are available in NEMA Sizes 00-7. Type S starters are designed for operation at 600 Volts AC, 50-60 Hertz.\u003cbr\u003e\u003cbr\u003e\nThese Square D starters from NEMA size 00-6 are provided with a melting alloy thermal overload relay as standard. Interchangeable thermal units are available in standard trip (Class 20) Sizes\n00-6, quick trip (Class 10) Sizes 00-4, and slow trip (Class 30) Sizes 00-3. Single-phase starters use one thermal unit, 3-phase starters use three thermal units.","brand":"Square D \/ Telemecanique","offers":[{"title":"Default Title","offer_id":48222162485486,"sku":"8536SBO2V02S","price":298.08,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/8536SBO2V02S-2.jpg?v=1782784327"},{"product_id":"8536sbo2v03","title":"8536SBO2V03","description":"Class 8536SBO2V03 Type S magnetic starters are used for full voltage starting and stopping AC squirrel cage motors. Motor overload protection is provided by melting alloy type thermal overload relays. Class 8536SB0 starters are available in NEMA Sizes 00-7. Type S starters are designed for operation at 600 Volts AC, 50-60 Hertz.\u003cbr\u003e\u003cbr\u003e\nThese Square D starters from NEMA size 00-6 are provided with a melting alloy thermal overload relay as standard. Interchangeable thermal units are available in standard trip (Class 20) Sizes\n00-6, quick trip (Class 10) Sizes 00-4, and slow trip (Class 30) Sizes 00-3. Single-phase starters use one thermal unit, 3-phase starters use three thermal units.","brand":"Square D \/ Telemecanique","offers":[{"title":"Default Title","offer_id":48222162518254,"sku":"8536SBO2V03","price":298.08,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/8536SBO2V03-2.jpg?v=1782784329"},{"product_id":"8536sbo2v03s","title":"8536SBO2V03S","description":"Class 8536SBO2V03S Type S magnetic starters are used for full voltage starting and stopping AC squirrel cage motors. Motor overload protection is provided by melting alloy type thermal overload relays. Class 8536SB0 starters are available in NEMA Sizes 00-7. Type S starters are designed for operation at 600 Volts AC, 50-60 Hertz.\u003cbr\u003e\u003cbr\u003e\nThese Square D starters from NEMA size 00-6 are provided with a melting alloy thermal overload relay as standard. Interchangeable thermal units are available in standard trip (Class 20) Sizes\n00-6, quick trip (Class 10) Sizes 00-4, and slow trip (Class 30) Sizes 00-3. Single-phase starters use one thermal unit, 3-phase starters use three thermal units.","brand":"Square D \/ Telemecanique","offers":[{"title":"Default Title","offer_id":48222162551022,"sku":"8536SBO2V03S","price":298.08,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/8536SBO2V03S-2.jpg?v=1782784331"},{"product_id":"8536sbo2v08","title":"8536SBO2V08","description":"Class 8536SBO2V08 Type S magnetic starters are used for full voltage starting and stopping AC squirrel cage motors. Motor overload protection is provided by melting alloy type thermal overload relays. Class 8536SB0 starters are available in NEMA Sizes 00-7. Type S starters are designed for operation at 600 Volts AC, 50-60 Hertz.\u003cbr\u003e\u003cbr\u003e\nThese Square D starters from NEMA size 00-6 are provided with a melting alloy thermal overload relay as standard. Interchangeable thermal units are available in standard trip (Class 20) Sizes\n00-6, quick trip (Class 10) Sizes 00-4, and slow trip (Class 30) Sizes 00-3. Single-phase starters use one thermal unit, 3-phase starters use three thermal units.","brand":"Square D \/ Telemecanique","offers":[{"title":"Default Title","offer_id":48222162583790,"sku":"8536SBO2V08","price":298.08,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/8536SBO2V08-2.jpg?v=1782784332"},{"product_id":"8536sbo2v08s","title":"8536SBO2V08S","description":"Class 8536SBO2V08S Type S magnetic starters are used for full voltage starting and stopping AC squirrel cage motors. Motor overload protection is provided by melting alloy type thermal overload relays. Class 8536SB0 starters are available in NEMA Sizes 00-7. Type S starters are designed for operation at 600 Volts AC, 50-60 Hertz.\u003cbr\u003e\u003cbr\u003e\nThese Square D starters from NEMA size 00-6 are provided with a melting alloy thermal overload relay as standard. Interchangeable thermal units are available in standard trip (Class 20) Sizes\n00-6, quick trip (Class 10) Sizes 00-4, and slow trip (Class 30) Sizes 00-3. Single-phase starters use one thermal unit, 3-phase starters use three thermal units.","brand":"Square D \/ Telemecanique","offers":[{"title":"Default Title","offer_id":48222162616558,"sku":"8536SBO2V08S","price":298.08,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/8536SBO2V08S-2.jpg?v=1782784333"},{"product_id":"8536sco3","title":"8536SC03","description":"Class 8536SCO3 magnetic starters are used for full voltage starting and stopping AC squirrel cage motors. Motor overload protection is provided by melting alloy type thermal overload relays. Class 8536SC0 starters are available in NEMA Sizes 00-7. Type S starters are designed for operation at 600 Volts AC, 50-60 Hertz.\u003cbr\u003e\u003cbr\u003e\nThese Square D starters from NEMA size 00-6 are provided with a melting alloy thermal overload relay as standard. Interchangeable thermal units are available in standard trip (Class 20) Sizes\n00-6, quick trip (Class 10) Sizes 00-4, and slow trip (Class 30) Sizes 00-3. Single-phase starters use one thermal unit, 3-phase starters use three thermal units.","brand":"Square D \/ Telemecanique","offers":[{"title":"Default Title","offer_id":48222162649326,"sku":"8536SCO3","price":370.84,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/8536SCO3-2.jpg?v=1782784335"},{"product_id":"8536sco3s","title":"8536SC03S","description":"Class 8536SCO3S Type S magnetic starters are used for full voltage starting and stopping AC squirrel cage motors. Motor overload protection is provided by melting alloy type thermal overload relays. Class 8536SC0 starters are available in NEMA Sizes 00-7. Type S starters are designed for operation at 600 Volts AC, 50-60 Hertz.\u003cbr\u003e\u003cbr\u003e\nThese Square D starters from NEMA size 00-6 are provided with a melting alloy thermal overload relay as standard. Interchangeable thermal units are available in standard trip (Class 20) Sizes\n00-6, quick trip (Class 10) Sizes 00-4, and slow trip (Class 30) Sizes 00-3. Single-phase starters use one thermal unit, 3-phase starters use three thermal units.","brand":"Square D \/ Telemecanique","offers":[{"title":"Default Title","offer_id":48222162682094,"sku":"8536SCO3S","price":370.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/8536SCO3S-2.jpg?v=1782784336"},{"product_id":"8536sco3v01s","title":"8536SC03V01S","description":"Class 8536SCO3V01S Type S magnetic starters are used for full voltage starting and stopping AC squirrel cage motors. Motor overload protection is provided by melting alloy type thermal overload relays. Class 8536SC0 starters are available in NEMA Sizes 00-7. Type S starters are designed for operation at 600 Volts AC, 50-60 Hertz.\u003cbr\u003e\u003cbr\u003e\nThese Square D starters from NEMA size 00-6 are provided with a melting alloy thermal overload relay as standard. Interchangeable thermal units are available in standard trip (Class 20) Sizes\n00-6, quick trip (Class 10) Sizes 00-4, and slow trip (Class 30) Sizes 00-3. Single-phase starters use one thermal unit, 3-phase starters use three thermal units.","brand":"Square D \/ Telemecanique","offers":[{"title":"Default Title","offer_id":48222162714862,"sku":"8536SCO3V01S","price":370.84,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/8536SCO3V01S-2.jpg?v=1782784336"},{"product_id":"8536sco3v02s","title":"8536SC03V02S","description":"Class 8536SCO3V02S Type S magnetic starters are used for full voltage starting and stopping AC squirrel cage motors. Motor overload protection is provided by melting alloy type thermal overload relays. Class 8536SC0 starters are available in NEMA Sizes 00-7. Type S starters are designed for operation at 600 Volts AC, 50-60 Hertz.\u003cbr\u003e\u003cbr\u003e\nThese Square D starters from NEMA size 00-6 are provided with a melting alloy thermal overload relay as standard. Interchangeable thermal units are available in standard trip (Class 20) Sizes\n00-6, quick trip (Class 10) Sizes 00-4, and slow trip (Class 30) Sizes 00-3. Single-phase starters use one thermal unit, 3-phase starters use three thermal units.","brand":"Square D \/ Telemecanique","offers":[{"title":"Default Title","offer_id":48222162780398,"sku":"8536SCO3V02S","price":370.84,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/8536SCO3V02S-2.jpg?v=1782784338"},{"product_id":"8536sco3v03s","title":"8536SC03V03S","description":"Class 8536SCO3V03S Type S magnetic starters are used for full voltage starting and stopping AC squirrel cage motors. Motor overload protection is provided by melting alloy type thermal overload relays. Class 8536SC0 starters are available in NEMA Sizes 00-7. Type S starters are designed for operation at 600 Volts AC, 50-60 Hertz.\u003cbr\u003e\u003cbr\u003e\nThese Square D starters from NEMA size 00-6 are provided with a melting alloy thermal overload relay as standard. Interchangeable thermal units are available in standard trip (Class 20) Sizes\n00-6, quick trip (Class 10) Sizes 00-4, and slow trip (Class 30) Sizes 00-3. Single-phase starters use one thermal unit, 3-phase starters use three thermal units.","brand":"Square D \/ Telemecanique","offers":[{"title":"Default Title","offer_id":48222162813166,"sku":"8536SCO3V03S","price":370.84,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/8536SCO3V03S-2.jpg?v=1782784340"},{"product_id":"8536sco3v08s","title":"8536SC03V08S","description":"Class 8536SCO3V08S Type S magnetic starters are used for full voltage starting and stopping AC squirrel cage motors. Motor overload protection is provided by melting alloy type thermal overload relays. Class 8536SC0 starters are available in NEMA Sizes 00-7. Type S starters are designed for operation at 600 Volts AC, 50-60 Hertz.\u003cbr\u003e\u003cbr\u003e\nThese Square D starters from NEMA size 00-6 are provided with a melting alloy thermal overload relay as standard. Interchangeable thermal units are available in standard trip (Class 20) Sizes\n00-6, quick trip (Class 10) Sizes 00-4, and slow trip (Class 30) Sizes 00-3. Single-phase starters use one thermal unit, 3-phase starters use three thermal units.","brand":"Square D \/ Telemecanique","offers":[{"title":"Default Title","offer_id":48222162845934,"sku":"8536SCO3V08S","price":370.84,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/8536SCO3V08S-2.jpg?v=1782784341"},{"product_id":"8536sdo1","title":"8536SD01","description":"Class 8536SDO1 \u003cdiv\u003emagnetic starters are used for full voltage starting and stopping AC squirrel cage motors. Motor overload protection is provided by melting alloy type thermal overload relays. Class 8536SD0 starters are available in NEMA Sizes 00-7. Type S starters are designed for operation at 600 Volts AC, 50-60 Hertz.\u003cbr\u003e\u003cbr\u003e\nThese Square D starters from NEMA size 00-6 are provided with a melting alloy thermal overload relay as standard. Interchangeable thermal units are available in standard trip (Class 20) Sizes\n00-6, quick trip (Class 10) Sizes 00-4, and slow trip (Class 30) Sizes 00-3. Single-phase starters use one thermal unit, 3-phase starters use three thermal units.\u003c\/div\u003e","brand":"Square D \/ Telemecanique","offers":[{"title":"Default Title","offer_id":48222162878702,"sku":"8536SDO1","price":634.46,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/8536SDO1-2.jpg?v=1782784342"},{"product_id":"8536sdo1s","title":"8536SD01S","description":"Class 8536SDO1S Type S magnetic starters are used for full voltage starting and stopping AC squirrel cage motors. Motor overload protection is provided by melting alloy type thermal overload relays. Class 8536SD0 starters are available in NEMA Sizes 00-7. Type S starters are designed for operation at 600 Volts AC, 50-60 Hertz.\u003cbr\u003e\u003cbr\u003e\nThese Square D starters from NEMA size 00-6 are provided with a melting alloy thermal overload relay as standard. Interchangeable thermal units are available in standard trip (Class 20) Sizes\n00-6, quick trip (Class 10) Sizes 00-4, and slow trip (Class 30) Sizes 00-3. Single-phase starters use one thermal unit, 3-phase starters use three thermal units.","brand":"Square D \/ Telemecanique","offers":[{"title":"Default Title","offer_id":48222162911470,"sku":"8536SDO1S","price":634.46,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/8536SDO1S-2.jpg?v=1782784343"},{"product_id":"8536sdo1v01s","title":"8536SDO1V01S","description":"Class 8536SDO1S Type S magnetic starters are used for full voltage starting and stopping AC squirrel cage motors. Motor overload protection is provided by melting alloy type thermal overload relays. Class 8536SD0 starters are available in NEMA Sizes 00-7. Type S starters are designed for operation at 600 Volts AC, 50-60 Hertz.\u003cbr\u003e\u003cbr\u003e\nThese Square D starters from NEMA size 00-6 are provided with a melting alloy thermal overload relay as standard. Interchangeable thermal units are available in standard trip (Class 20) Sizes\n00-6, quick trip (Class 10) Sizes 00-4, and slow trip (Class 30) Sizes 00-3. Single-phase starters use one thermal unit, 3-phase starters use three thermal units.","brand":"Square D \/ Telemecanique","offers":[{"title":"Default Title","offer_id":48222162944238,"sku":"8536SDO1V01S","price":634.46,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/8536SDO1V01S-2.jpg?v=1782784346"},{"product_id":"8536sdo1v02s","title":"8536SDO1V02S","description":"Class 8536SDO1S Type S magnetic starters are used for full voltage starting and stopping AC squirrel cage motors. Motor overload protection is provided by melting alloy type thermal overload relays. Class 8536SD0 starters are available in NEMA Sizes 00-7. Type S starters are designed for operation at 600 Volts AC, 50-60 Hertz.\u003cbr\u003e\u003cbr\u003e\nThese Square D starters from NEMA size 00-6 are provided with a melting alloy thermal overload relay as standard. Interchangeable thermal units are available in standard trip (Class 20) Sizes\n00-6, quick trip (Class 10) Sizes 00-4, and slow trip (Class 30) Sizes 00-3. Single-phase starters use one thermal unit, 3-phase starters use three thermal units.","brand":"Square D \/ Telemecanique","offers":[{"title":"Default Title","offer_id":48222162977006,"sku":"8536SDO1V02S","price":634.46,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/8536SDO1V02S-2.jpg?v=1782784346"},{"product_id":"8536sdo1v03s","title":"8536SDO1V03S","description":"Class 8536SDO1S Type S magnetic starters are used for full voltage starting and stopping AC squirrel cage motors. Motor overload protection is provided by melting alloy type thermal overload relays. Class 8536SD0 starters are available in NEMA Sizes 00-7. Type S starters are designed for operation at 600 Volts AC, 50-60 Hertz.\u003cbr\u003e\u003cbr\u003e\nThese Square D starters from NEMA size 00-6 are provided with a melting alloy thermal overload relay as standard. Interchangeable thermal units are available in standard trip (Class 20) Sizes\n00-6, quick trip (Class 10) Sizes 00-4, and slow trip (Class 30) Sizes 00-3. Single-phase starters use one thermal unit, 3-phase starters use three thermal units.","brand":"Square D \/ Telemecanique","offers":[{"title":"Default Title","offer_id":48222163009774,"sku":"8536SDO1V03S","price":634.46,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/8536SDO1V03S-2.jpg?v=1782784347"}],"url":"https:\/\/www.imc-direct.com\/collections\/square-d-telemecanique.oembed?page=58","provider":"IMC Direct","version":"1.0","type":"link"}