{"title":"PKZ2 Starters","description":"\u003cp\u003eThe Moeller PKZ2 series of starters come with removable thermal trip units with AMP ranges from 1A to 40A.  Each starter can be combined with a S-PKZ2 contactor to form a Type E self protected combination motor controller\u003c\/p\u003e","products":[{"product_id":"nhi11-pkz2","title":"NHI11-PKZ2","description":"The Moeller NHI11-PKZ2 auxiliary contact is a side mounted auxiliary contact for the \u003ca href=\"\/products\/pkz2-zm-25\"\u003eMoeller PKZ2\u003c\/a\u003e series of motor starters.  It has a snap-on installation and requires no additional wiring to the base unit.  It comes with 1 normally open and 1 normally closed base contacts and only adds a minimal amount of width to the base unit","brand":"Other","offers":[{"title":"Default Title","offer_id":48222449762542,"sku":"NHI11-PKZ2","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/NHI11-PKZ2-2.jpg?v=1782788800"},{"product_id":"nhi22-pkz2","title":"NHI22-PKZ2","description":"\u003cp\u003eThe Moeller NHI22-PKZ2 auxiliary contact is a side mounted auxiliary contact for the PKZ2 series of motor starters.  It has a snap-on installation and requires no additional wiring to the base unit.  It comes with 2 normally open and 2 normally closed base contacts and only adds a minimal amount of width to the base unit\u003c\/p\u003e","brand":"Other","offers":[{"title":"Default Title","offer_id":48222449893614,"sku":"NHI22-PKZ2","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/NHI22-PKZ2-2.jpg?v=1782788806"},{"product_id":"pkz2","title":"PKZ2","description":"\u003cp\u003eStocking a lot of devices with different over-current and short circuit trip characteristics is an expensive task. Even if you did, the time it takes rewiring devices to accommodate application changes is an avoidable waste. The PKZ2 is the first self-protected combination controller in the industry with interchangeable and adjustable, “tool-less,” plug-in trip modules. Eleven different ZM-PKZ2 modules cover the range from fractional to 30 HP at 460V AC (25HP @ 600V AC). Exchanging trip modules can be done in seconds… without rewiring power conductors.\u003c\/p\u003e","brand":"Other","offers":[{"title":"Default Title","offer_id":48222452351214,"sku":"PKZ2","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/PKZ2-2.jpg?v=1782788843"},{"product_id":"pkz2-xah","title":"PKZ2-XAH","description":"The PKZ2-XAH is an extension shaft that mounts the \u003ca href=\"\/products\/pkz2-zm-25\"\u003eMoeller PKZ2\u003c\/a\u003e handles on the door to the PKZ2 unit itself within the panel.  This shaft can be cut to various lengths and provides for a lockout mechanism that only allows for the door to be opened when the base unit is in the OFF position.","brand":"Other","offers":[{"title":"Default Title","offer_id":48222452383982,"sku":"PKZ2-XAH","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/PKZ2-XAH-2.jpg?v=1782788846"},{"product_id":"pkz2-xh","title":"PKZ2-XH","description":"The PKZ2-XH is a black through-the door rotary operator provides for operation of the \u003ca href=\"\/products\/pkz2-zm-25\"\u003eMoeller PKZ2\u003c\/a\u003e Motor Starter within a panel and with the door closed.  The standard unit provides a door interlock so the door cannot be opened when the unit is in the \"ON\" position.","brand":"Other","offers":[{"title":"Default Title","offer_id":48222452416750,"sku":"PKZ2-XH","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/PKZ2-XH-2.jpg?v=1782788847"},{"product_id":"pkz2-xrh","title":"PKZ2-XRH","description":"\u003cp\u003eThe PKZ2-XRH is a red\/yellow Emergency Stop through-the door rotary operator provides for operation of the PKZ2 Motor Starter within a panel and with the door closed.  The standard unit provides a door interlock so the door cannot be opened when the unit is in the \"ON\" position.\u003c\/p\u003e","brand":"Other","offers":[{"title":"Default Title","offer_id":48222452449518,"sku":"PKZ2-XRH","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/PKZ2-XRH-2.jpg?v=1782788849"},{"product_id":"pkz2-zm-1","title":"PKZ2\/ZM-1","description":"\u003cp\u003eStocking a lot of devices with different over-current and short circuit trip characteristics is an expensive task. Even if you did, the time it takes rewiring devices to accommodate application changes is an avoidable waste. The PKZ2 is the first self-protected combination controller in the industry with interchangeable and adjustable, “tool-less,” plug-in trip modules. Eleven different ZM-PKZ2 modules cover the range from fractional to 30 HP at 460V AC (25HP @ 600V AC). Exchanging trip modules can be done in seconds… without rewiring power conductors.\u003c\/p\u003e","brand":"Other","offers":[{"title":"Default Title","offer_id":48222452482286,"sku":"PKZ2-ZM-1","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/PKZ2-ZM-1-2.jpg?v=1782788849"},{"product_id":"pkz2-zm-1-6","title":"PKZ2\/ZM-1.6","description":"\u003cp\u003eStocking a lot of devices with different over-current and short circuit trip characteristics is an expensive task. Even if you did, the time it takes rewiring devices to accommodate application changes is an avoidable waste. The PKZ2 is the first self-protected combination controller in the industry with interchangeable and adjustable, “tool-less,” plug-in trip modules. Eleven different ZM-PKZ2 modules cover the range from fractional to 30 HP at 460V AC (25HP @ 600V AC). Exchanging trip modules can be done in seconds… without rewiring power conductors.\u003c\/p\u003e","brand":"Other","offers":[{"title":"Default Title","offer_id":48222452515054,"sku":"PKZ2-ZM-1.6","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/PKZ2-ZM-1.6-2.jpg?v=1782788852"},{"product_id":"pkz2-zm-10","title":"PKZ2\/ZM-10","description":"\u003cp\u003eStocking a lot of devices with different over-current and short circuit trip characteristics is an expensive task. Even if you did, the time it takes rewiring devices to accommodate application changes is an avoidable waste. The PKZ2 is the first self-protected combination controller in the industry with interchangeable and adjustable, “tool-less,” plug-in trip modules. Eleven different ZM-PKZ2 modules cover the range from fractional to 30 HP at 460V AC (25HP @ 600V AC). Exchanging trip modules can be done in seconds… without rewiring power conductors.\u003c\/p\u003e","brand":"Other","offers":[{"title":"Default Title","offer_id":48222452547822,"sku":"PKZ2-ZM-10","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/PKZ2-ZM-10-2.jpg?v=1782788853"},{"product_id":"pkz2-zm-16","title":"PKZ2\/ZM-16","description":"\u003cp\u003eStocking a lot of devices with different over-current and short circuit trip characteristics is an expensive task. Even if you did, the time it takes rewiring devices to accommodate application changes is an avoidable waste. The PKZ2 is the first self-protected combination controller in the industry with interchangeable and adjustable, “tool-less,” plug-in trip modules. Eleven different ZM-PKZ2 modules cover the range from fractional to 30 HP at 460V AC (25HP @ 600V AC). Exchanging trip modules can be done in seconds… without rewiring power conductors.\u003c\/p\u003e","brand":"Other","offers":[{"title":"Default Title","offer_id":48222452580590,"sku":"PKZ2-ZM-16","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/PKZ2-ZM-16-2.jpg?v=1782788855"},{"product_id":"pkz2-zm-2-4","title":"PKZ2\/ZM-2.4","description":"\u003cp\u003eStocking a lot of devices with different over-current and short circuit trip characteristics is an expensive task. Even if you did, the time it takes rewiring devices to accommodate application changes is an avoidable waste. The PKZ2 is the first self-protected combination controller in the industry with interchangeable and adjustable, “tool-less,” plug-in trip modules. Eleven different ZM-PKZ2 modules cover the range from fractional to 30 HP at 460V AC (25HP @ 600V AC). Exchanging trip modules can be done in seconds… without rewiring power conductors.\u003c\/p\u003e","brand":"Other","offers":[{"title":"Default Title","offer_id":48222452613358,"sku":"PKZ2-ZM-2.4","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/PKZ2-ZM-2.4-2.jpg?v=1782788856"},{"product_id":"pkz2-zm-25","title":"PKZ2\/ZM-25","description":"\u003cp\u003eStocking a lot of devices with different over-current and short circuit trip characteristics is an expensive task. Even if you did, the time it takes rewiring devices to accommodate application changes is an avoidable waste. The PKZ2 is the first self-protected combination controller in the industry with interchangeable and adjustable, “tool-less,” plug-in trip modules. Eleven different ZM-PKZ2 modules cover the range from fractional to 30 HP at 460V AC (25HP @ 600V AC). Exchanging trip modules can be done in seconds… without rewiring power conductors.\u003c\/p\u003e","brand":"Other","offers":[{"title":"Default Title","offer_id":48222452711662,"sku":"PKZ2-ZM-25","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/PKZ2-ZM-25-2.jpg?v=1782788859"},{"product_id":"pkz2-zm-32","title":"PKZ2\/ZM-32","description":"\u003cp\u003eStocking a lot of devices with different over-current and short circuit trip characteristics is an expensive task. Even if you did, the time it takes rewiring devices to accommodate application changes is an avoidable waste. The PKZ2 is the first self-protected combination controller in the industry with interchangeable and adjustable, “tool-less,” plug-in trip modules. Eleven different ZM-PKZ2 modules cover the range from fractional to 30 HP at 460V AC (25HP @ 600V AC). Exchanging trip modules can be done in seconds… without rewiring power conductors.\u003c\/p\u003e","brand":"Other","offers":[{"title":"Default Title","offer_id":48222452744430,"sku":"PKZ2-ZM-32","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/PKZ2-ZM-32-2.jpg?v=1782788859"},{"product_id":"pkz2-zm-4","title":"PKZ2\/ZM-4","description":"\u003cp\u003eStocking a lot of devices with different over-current and short circuit trip characteristics is an expensive task. Even if you did, the time it takes rewiring devices to accommodate application changes is an avoidable waste. The PKZ2 is the first self-protected combination controller in the industry with interchangeable and adjustable, “tool-less,” plug-in trip modules. Eleven different ZM-PKZ2 modules cover the range from fractional to 30 HP at 460V AC (25HP @ 600V AC). Exchanging trip modules can be done in seconds… without rewiring power conductors.\u003c\/p\u003e","brand":"Other","offers":[{"title":"Default Title","offer_id":48222452777198,"sku":"PKZ2-ZM-4","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/PKZ2-ZM-4-2.jpg?v=1782788862"},{"product_id":"pkz2-zm-40","title":"PKZ2\/ZM-40","description":"\u003cp\u003eStocking a lot of devices with different over-current and short circuit trip characteristics is an expensive task. Even if you did, the time it takes rewiring devices to accommodate application changes is an avoidable waste. The PKZ2 is the first self-protected combination controller in the industry with interchangeable and adjustable, “tool-less,” plug-in trip modules. Eleven different ZM-PKZ2 modules cover the range from fractional to 30 HP at 460V AC (25HP @ 600V AC). Exchanging trip modules can be done in seconds… without rewiring power conductors.\u003c\/p\u003e","brand":"Other","offers":[{"title":"Default Title","offer_id":48222452809966,"sku":"PKZ2-ZM-40","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/PKZ2-ZM-40-2.jpg?v=1782788863"},{"product_id":"pkz2-zm-6","title":"PKZ2\/ZM-6","description":"\u003cp\u003eStocking a lot of devices with different over-current and short circuit trip characteristics is an expensive task. Even if you did, the time it takes rewiring devices to accommodate application changes is an avoidable waste. The PKZ2 is the first self-protected combination controller in the industry with interchangeable and adjustable, “tool-less,” plug-in trip modules. Eleven different ZM-PKZ2 modules cover the range from fractional to 30 HP at 460V AC (25HP @ 600V AC). Exchanging trip modules can be done in seconds… without rewiring power conductors.\u003c\/p\u003e","brand":"Other","offers":[{"title":"Default Title","offer_id":48222452842734,"sku":"PKZ2-ZM-6","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/PKZ2-ZM-6-2.jpg?v=1782788865"},{"product_id":"zm-1-pkz2","title":"ZM-1-PKZ2","description":"\u003cp\u003eEach trip module has a coordinated, independently adjustable, over-current trip (yellow dial) for overload protection (0.6 -1.0 x Iu) and an adjustable, instantaneous, magnetic trip (red dial) for short circuit protection (8.5 – 14 x Iu). Each dial can be set in accordance with the motor full load current and inrush, making it ideal for installations with varying motor efficiencies. All trip modules have temperature compensation from –5° C (23° F) to +40° C (102° F) and include built-in single phase protection.\u003c\/p\u003e\n\n\u003cp\u003eIn the event of an over-current or short-circuit situation, standard ZM trip modules cause the motor protective switch mechanism to open and disconnect power to the load, much like the operation of an inverse time molded case breaker. They make excellent manual motor starters, not only because of their all-in-one design and excellent thermal protection, but because they also provide “close” individual protection from short circuits.\u003c\/p\u003e","brand":"Other","offers":[{"title":"Default Title","offer_id":48222600823022,"sku":"ZM-1-PKZ2","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/ZM-1-PKZ2-2.jpg?v=1782790741"},{"product_id":"zm-1-6-pkz2","title":"ZM-1.6-PKZ2","description":"\u003cp\u003eEach trip module has a coordinated, independently adjustable, over-current trip (yellow dial) for overload protection (0.6 -1.0 x Iu) and an adjustable, instantaneous, magnetic trip (red dial) for short circuit protection (8.5 – 14 x Iu). Each dial can be set in accordance with the motor full load current and inrush, making it ideal for installations with varying motor efficiencies. All trip modules have temperature compensation from –5° C (23° F) to +40° C (102° F) and include built-in single phase protection.\u003c\/p\u003e\n\n\u003cp\u003eIn the event of an over-current or short-circuit situation, standard ZM trip modules cause the motor protective switch mechanism to open and disconnect power to the load, much like the operation of an inverse time molded case breaker. They make excellent manual motor starters, not only because of their all-in-one design and excellent thermal protection, but because they also provide “close” individual protection from short circuits.\u003c\/p\u003e","brand":"Other","offers":[{"title":"Default Title","offer_id":48222600855790,"sku":"ZM-1.6-PKZ2","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/ZM-1.6-PKZ2-2.jpg?v=1782790741"},{"product_id":"zm-10-pkz2","title":"ZM-10-PKZ2","description":"\u003cp\u003eEach trip module has a coordinated, independently adjustable, over-current trip (yellow dial) for overload protection (0.6 -1.0 x Iu) and an adjustable, instantaneous, magnetic trip (red dial) for short circuit protection (8.5 – 14 x Iu). Each dial can be set in accordance with the motor full load current and inrush, making it ideal for installations with varying motor efficiencies. All trip modules have temperature compensation from –5° C (23° F) to +40° C (102° F) and include built-in single phase protection.\u003c\/p\u003e\n\n\u003cp\u003eIn the event of an over-current or short-circuit situation, standard ZM trip modules cause the motor protective switch mechanism to open and disconnect power to the load, much like the operation of an inverse time molded case breaker. They make excellent manual motor starters, not only because of their all-in-one design and excellent thermal protection, but because they also provide “close” individual protection from short circuits.\u003c\/p\u003e","brand":"Other","offers":[{"title":"Default Title","offer_id":48222600888558,"sku":"ZM-10-PKZ2","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/ZM-10-PKZ2-2.jpg?v=1782790742"},{"product_id":"zm-16-pkz2","title":"ZM-16-PKZ2","description":"\u003cp\u003eEach trip module has a coordinated, independently adjustable, over-current trip (yellow dial) for overload protection (0.6 -1.0 x Iu) and an adjustable, instantaneous, magnetic trip (red dial) for short circuit protection (8.5 – 14 x Iu). Each dial can be set in accordance with the motor full load current and inrush, making it ideal for installations with varying motor efficiencies. All trip modules have temperature compensation from –5° C (23° F) to +40° C (102° F) and include built-in single phase protection.\u003c\/p\u003e\n\n\u003cp\u003eIn the event of an over-current or short-circuit situation, standard ZM trip modules cause the motor protective switch mechanism to open and disconnect power to the load, much like the operation of an inverse time molded case breaker. They make excellent manual motor starters, not only because of their all-in-one design and excellent thermal protection, but because they also provide “close” individual protection from short circuits.\u003c\/p\u003e","brand":"Other","offers":[{"title":"Default Title","offer_id":48222600921326,"sku":"ZM-16-PKZ2","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/ZM-16-PKZ2-2.jpg?v=1782790743"},{"product_id":"zm-2-4-pkz2","title":"ZM-2.4-PKZ2","description":"\u003cp\u003eEach trip module has a coordinated, independently adjustable, over-current trip (yellow dial) for overload protection (0.6 -1.0 x Iu) and an adjustable, instantaneous, magnetic trip (red dial) for short circuit protection (8.5 – 14 x Iu). Each dial can be set in accordance with the motor full load current and inrush, making it ideal for installations with varying motor efficiencies. All trip modules have temperature compensation from –5° C (23° F) to +40° C (102° F) and include built-in single phase protection.\u003c\/p\u003e\n\n\u003cp\u003eIn the event of an over-current or short-circuit situation, standard ZM trip modules cause the motor protective switch mechanism to open and disconnect power to the load, much like the operation of an inverse time molded case breaker. They make excellent manual motor starters, not only because of their all-in-one design and excellent thermal protection, but because they also provide “close” individual protection from short circuits.\u003c\/p\u003e","brand":"Other","offers":[{"title":"Default Title","offer_id":48222600954094,"sku":"ZM-2.4-PKZ2","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/ZM-2.4-PKZ2-2.jpg?v=1782790747"},{"product_id":"zm-25-pkz2","title":"ZM-25-PKZ2","description":"\u003cp\u003eEach trip module has a coordinated, independently adjustable, over-current trip (yellow dial) for overload protection (0.6 -1.0 x Iu) and an adjustable, instantaneous, magnetic trip (red dial) for short circuit protection (8.5 – 14 x Iu). Each dial can be set in accordance with the motor full load current and inrush, making it ideal for installations with varying motor efficiencies. All trip modules have temperature compensation from –5° C (23° F) to +40° C (102° F) and include built-in single phase protection.\u003c\/p\u003e\n\n\u003cp\u003eIn the event of an over-current or short-circuit situation, standard ZM trip modules cause the motor protective switch mechanism to open and disconnect power to the load, much like the operation of an inverse time molded case breaker. They make excellent manual motor starters, not only because of their all-in-one design and excellent thermal protection, but because they also provide “close” individual protection from short circuits.\u003c\/p\u003e","brand":"Other","offers":[{"title":"Default Title","offer_id":48222600986862,"sku":"ZM-25-PKZ2","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/ZM-25-PKZ2-2.jpg?v=1782790747"},{"product_id":"zm-32-pkz2","title":"ZM-32-PKZ2","description":"\u003cp\u003eEach trip module has a coordinated, independently adjustable, over-current trip (yellow dial) for overload protection (0.6 -1.0 x Iu) and an adjustable, instantaneous, magnetic trip (red dial) for short circuit protection (8.5 – 14 x Iu). Each dial can be set in accordance with the motor full load current and inrush, making it ideal for installations with varying motor efficiencies. All trip modules have temperature compensation from –5° C (23° F) to +40° C (102° F) and include built-in single phase protection.\u003c\/p\u003e\n\n\u003cp\u003eIn the event of an over-current or short-circuit situation, standard ZM trip modules cause the motor protective switch mechanism to open and disconnect power to the load, much like the operation of an inverse time molded case breaker. They make excellent manual motor starters, not only because of their all-in-one design and excellent thermal protection, but because they also provide “close” individual protection from short circuits.\u003c\/p\u003e","brand":"Other","offers":[{"title":"Default Title","offer_id":48222601019630,"sku":"ZM-32-PKZ2","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/ZM-32-PKZ2-2.jpg?v=1782790748"},{"product_id":"zm-4-pkz2","title":"ZM-4-PKZ2","description":"\u003cp\u003eEach trip module has a coordinated, independently adjustable, over-current trip (yellow dial) for overload protection (0.6 -1.0 x Iu) and an adjustable, instantaneous, magnetic trip (red dial) for short circuit protection (8.5 – 14 x Iu). Each dial can be set in accordance with the motor full load current and inrush, making it ideal for installations with varying motor efficiencies. All trip modules have temperature compensation from –5° C (23° F) to +40° C (102° F) and include built-in single phase protection.\u003c\/p\u003e\n\n\u003cp\u003eIn the event of an over-current or short-circuit situation, standard ZM trip modules cause the motor protective switch mechanism to open and disconnect power to the load, much like the operation of an inverse time molded case breaker. They make excellent manual motor starters, not only because of their all-in-one design and excellent thermal protection, but because they also provide “close” individual protection from short circuits.\u003c\/p\u003e","brand":"Other","offers":[{"title":"Default Title","offer_id":48222601052398,"sku":"ZM-4-PKZ2","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/ZM-4-PKZ2-2.jpg?v=1782790748"},{"product_id":"zm-40-pkz2","title":"ZM-40-PKZ2","description":"\u003cp\u003eEach trip module has a coordinated, independently adjustable, over-current trip (yellow dial) for overload protection (0.6 -1.0 x Iu) and an adjustable, instantaneous, magnetic trip (red dial) for short circuit protection (8.5 – 14 x Iu). Each dial can be set in accordance with the motor full load current and inrush, making it ideal for installations with varying motor efficiencies. All trip modules have temperature compensation from –5° C (23° F) to +40° C (102° F) and include built-in single phase protection.\u003c\/p\u003e\n\n\u003cp\u003eIn the event of an over-current or short-circuit situation, standard ZM trip modules cause the motor protective switch mechanism to open and disconnect power to the load, much like the operation of an inverse time molded case breaker. They make excellent manual motor starters, not only because of their all-in-one design and excellent thermal protection, but because they also provide “close” individual protection from short circuits.\u003c\/p\u003e","brand":"Other","offers":[{"title":"Default Title","offer_id":48222601085166,"sku":"ZM-40-PKZ2","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/ZM-40-PKZ2-2.jpg?v=1782790753"},{"product_id":"zm-6-pkz2","title":"ZM-6-PKZ2","description":"\u003cp\u003eEach trip module has a coordinated, independently adjustable, over-current trip (yellow dial) for overload protection (0.6 -1.0 x Iu) and an adjustable, instantaneous, magnetic trip (red dial) for short circuit protection (8.5 – 14 x Iu). Each dial can be set in accordance with the motor full load current and inrush, making it ideal for installations with varying motor efficiencies. All trip modules have temperature compensation from –5° C (23° F) to +40° C (102° F) and include built-in single phase protection.\u003c\/p\u003e\n\n\u003cp\u003eIn the event of an over-current or short-circuit situation, standard ZM trip modules cause the motor protective switch mechanism to open and disconnect power to the load, much like the operation of an inverse time molded case breaker. They make excellent manual motor starters, not only because of their all-in-one design and excellent thermal protection, but because they also provide “close” individual protection from short circuits.\u003c\/p\u003e","brand":"Other","offers":[{"title":"Default Title","offer_id":48222601117934,"sku":"ZM-6-PKZ2","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/0802\/3790\/files\/ZM-6-PKZ2-2.jpg?v=1782790753"}],"url":"https:\/\/www.imc-direct.com\/collections\/pkz2-starters.oembed","provider":"IMC Direct","version":"1.0","type":"link"}